3P Poles Pv Lightning Protection For Power Transfer Equipment

3P Poles Pv Lightning Protection For Power Transfer Equipment

Product Details:

Place of Origin: Dongguan China
Brand Name: Uchi
Certification: CE / SGS / ISO9001
Model Number: OBV5-C40-PV

Payment & Shipping Terms:

Minimum Order Quantity: 200 piece
Price: Negotiate
Packaging Details: export package / Negotiate
Delivery Time: 5-15 days after payment
Payment Terms: T/T, L/C, Western Union
Supply Ability: 60000 pieces per month
Get Best Price Contact Now

Detail Information

Name: Lightning Surge Arrester Poles Number: 3P
In: 20KA Imax: 40KA
Connection: By Screw Terminals: 4-25 Mm2 Network Voltage: 800 Vdc
Mounting: Symmetrical Rail 35 Mm CertificationCE,CQC: CE / CQC / SGS
High Light:

lightning proof surge protector

,

3P Poles pv lightning protection

,

Power Transfer Equipment pv lightning protection

Product Description

40KA PV Surge Protector Connected By Screw Terminals: 4-25 Mm2

 

OBV5-C40-PV

 

Prewired modular complete unit for use in photovoltaic systems consisting of a base part and plug-in protection modules

Combined disconnection and short-circuiting device with safe electrical isolation in the protection module prevents fire damage resulting from d.c. switching arcs (patented SCI principle)

Tried and tested fault-resistant Y circuit of the OBV6-C40-PV prevents damage to the surge protective device in case of insulation faults in the generator circuit.

Integrated d.c. fuse allows safe replacement of protection modules without arc formation.


Technical Parameters

 

Model: OBV5-C40-PV
Network voltage 500Vdc 600Vdc 800Vdc 900Vdc 1000 Vdc  
Max. operating voltage Uc 530Vdc 630Vdc 840Vdc 950Vdc 1060 Vdc  
Nominal discharge current ln 20kA
Max. discharge current lmax 40kA
Protection level (at In) Up 1.8kV 2.5kV 2.8kV 3.0kV 3.2kV  
Disconnector
Thermal Disconnector Internal
Mechanical characteristics
Connection by screw terminals: 4-25 mm2
Disconnection indicator 1 mechanical indicator by pole
Mounting symmetrical rail 35 mm
Operating temperature -40/+85°C
Protection class IP20
Standards compliance
NF EN 61643-11 France Parafoudre Basse Tension - Essais Classe II
IEC 61643-1 International Low Voltage SPD - Test Class II
EN 61643-11 Europe Parafoudre Basse Tension - Essais Classe II

 

Feature&Benefits
 
-Easy installation or retrofit

-Din-rail mountable
-Fail-safe /self-protected designRemote indicator (optional) with 3pin NO/NC contact
-IP20 finger-safe designVisual indicator
-Small foot print
 

Note: The system lightning protection does not guarantee that the equipment will not be 100% damaged by lightning; the power system must be multi-level lightning protection;
The complete lightning protection system includes external lightning protection and internal lightning protection. External lightning protection refers to: lightning receptors, down conductors, and grounding bodies, which are mainly used to defend against direct lightning strikes. Internal lightning protection includes: shielding, reasonable wiring, safe distance, equipotential connection, overvoltage protection, etc., mainly used to prevent lightning induction, ground potential counterattack, lightning wave intrusion, etc.


Application


●AC/DC distribution
●Power supplies
●Industrial automation
●Telecommunications
●Motor controls systems
●PLC applications
●Power transfer equipment
●HVAC applications
● AC drives
●UPS systems
●Security systems
●IT/Data centers
 

Tip: Lightning protection is probabilistic protection, and we cannot provide 100% protection.


First, lightning discharge itself has a certain degree of randomness, and lightning parameters have certain statistical properties, which determines that all protective measures based on these statistical characteristics of lightning parameters cannot provide 100% protection. Such as: direct lightning protection-shielding characteristics; lightning current amplitude, waveform, etc. have statistical properties;
Second, the lightning protection equipment cannot prevent the formation of lightning flashes;
Third, lightning protection devices cannot ideally eliminate all interference voltages/currents. The fundamental purpose of taking protective measures is to ensure that most of the energy caused by interference does not spread to the vulnerable parts of the device and the staff.
Finally, the cost of protection against high-level surges with a small probability of occurrence has risen sharply.


Others


Technology SPD parameter(Note:According to user requirement ,can be customized Uc=140V,440V,550V,voltage range of range of the SPD):

Type No. Rated Voltage(V) Un Continuous Voltage Uc(V~) Standard Discharge Current In(KA)

Max Discharge Current
Imax(KA)

Protection Level(KA~) Response Time(ns)
DGM1(2)-D5 220/380

275/320
385/420

5 10 1.2 ≤25
DGM1(2)-D10 10 2 1.6
DGM1(2)-C20 20 40 1.8
DGM13-B30 30 60 .2.2
DGM3(4)-B40 10 80 2.4
DGM(4)-B60 60 100 2.8
DGM-N-PE 220/255 40/60 60/80 1.2 ≤100

 

Surges in telecom andsignalling networks
Surges tend to induce currents in allmetal conductors; not only are thepower lines affected, but so are allcables to a greater or lesser extent,depending on the distance to the focusof the surge.
Although a lower current is induced,the effect produced is equally or moredestructive, due to the greatersensitivity of electronic equipmentconnected to communications lines(telephone, Ethernet, R, etc.).

 
Importance of theground connection
Overvoltage protectors (SPD) divert excess energy toground, so limiting the peak voltage to an acceptablevalue for connected electrical equipment.
A ground connection in adequate condition is, therefore,a key aspect for effective protection against overvoltages.Monitoring ground connection condition guaranteesproper operation of surge protection devices.

 
What skills should lightning protectors have in the selection?
 
1.Confirm power supply system
First of all, you must determine what your power distribution system is like, whether it is TT, TN or IT system. After determining the power distribution system, you can choose the protection mode and wiring method of the lightning arrester to select the appropriate lightning arrester.
For example, TN-C uses 3P lightning protection device, TN-S uses 4P, TT uses 3P+N, etc.
 
2.Know the main parameters of the lightning arrester.
 
FAQ

 
Q: Can I get some samples?
A: Yes, Sample orders welcomed.
 
Q: Can I use my own Logo or design on goods?
A: Yes, Customized logo and design on mass production are available.
 
Q:What is the delivery time?
A: 3 days for samples, 7-15 days for mass production.
 
Q: What is the payment term?
A: T/T, L/C at sight, West union , Paypal, etc.

Want to Know more details about this product
I am interested in 3P Poles Pv Lightning Protection For Power Transfer Equipment could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.